Old tiled stove: replace the heating insert, not the whole stove

Often it is not the whole tiled stove that has reached the end of its life, just the insert inside. In that case, you can keep the tiled casing and renew the insert.

Old tiled stove: replace the heating insert, not the whole stove

Your tiled stove is beautiful, but the fire inside it has lost its spark? Then the problem is often the heating insert, not the tiles. The good news: the tiled casing can stay.

How to recognise a worn-out insert

  • The firebrick in the combustion chamber is badly cracked or crumbling.
  • The door no longer closes tightly.
  • The stove draws poorly or smokes when you light it.
  • It uses a lot of wood and still does not get properly warm.

What happens during the replacement

The old insert is removed without destroying the tiles. We then fit a new insert that suits the size and the chimney, and close the tiled casing again. Whether and how the heat is stored in the casing is something we discuss with you beforehand.

Why replacing it often makes sense

The tiles and the casing of an old tiled stove are usually still in good condition, and are often the most beautiful part of the stove. The insert, on the other hand, is put under heavy strain by the fire. A new insert brings modern combustion with better air flow and a tightly sealing door. You keep your familiar stove and the look of your room, and the heat is used more efficiently.

When building a new one is better

If the casing itself is damaged, for example by cracks in the masonry or loose tiles, or if the chimney is not suitable for a new insert, replacing the insert is not always worthwhile. We check this on site too and tell you honestly.

What is clarified beforehand

  • Is the chimney in good order and does it suit the new insert?
  • Which requirements apply to your appliance? We agree this with your district chimney sweep.
  • Does the insert fit into the existing casing?

The first step

Send us photos of your tiled stove, of the combustion chamber and, if available, of the rating plate. We will then tell you whether the replacement is worthwhile. Call us on 05374 66092 or write to us via the contact page.